Filter Results By:

Products

Applications

Manufacturers

Showing results: 376 - 390 of 664 items found.

  • Telemetry

    ESI Technology Ltd

    Single channel system, offering wireless transfer of a single analogue signal, either 4-20mA or DC voltage. Mixed signal radio telemetry solution. Analogue I/O: 2x 2-40mA or DC Voltage. Digital I/O: 2x volt free or optional pulse counting required. Multi-channel radio telemetry system, 4 Analogue and 8 digital inputs. Significant signal connectivity and data transfer in a standard package.12 I/O channels allow greater signal monitoring capability SENSOR LINK Compact wireless telemetry link for any strain gauge sensor or RTD. Transmissions distance 1 to 300 meters. Licence free radio operation.16 bit ADC resolution.

  • Qualification and Quality Control Tests

    Techsquare - Techimp HQ S.r.L

    New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.

  • Portable Calibrator

    MC141 - Powertek LLC

    Voltage range from 0 to 750 V DC/AC with uncertainty 0.01% Current range from 0 to 2 A DC/AC with uncertainty 0.02 % Calibrated sinusoidal output signal DC - 1kHz. Set standard resistors from 10 Ohm to 100 MOhm in decade values with uncertainty 0.02 %. TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250 oC to 1850 oC

  • Reconfigurable FPGA w/ AD/DA & Digital I/O PCIe Mini Card

    TMPE627 - TEWS Technologies GmbH

    The TMPE627 is a standard full PCI Express Mini Card, providing a user programmable Xilinx Artix-7 7A50T FPGA. The TMPE627 provides 14 ESD-protected 5 V-tolerant TTL lines. All I/O lines are individually programmable as input or output. TTL I/O lines can be set to high, low, or tristate. Each TTL I/O line has a pull-resistor to a common programmable pull-up voltage that can be set so +3.3 V, +5 V and GND.

  • 18 Inch Universal Flex Current Probe Accessory

    FLIR TA74 - Teledyne FLIR

    The FLIR TA74 adds capabilities, simplifies challenges, and gives you the best readings with your existing meter. The narrow, 18-inch long flexible coil clamp and locking mechanism allows you take measurements in tight or awkward spots – ideal for multiple conductor measurements, double-wrap requirements, and deeper access. The connection is a standard banana plug and the output is a voltage signal, so it’s compatible with most DMMs and clamp meters, regardless of brand.

  • Voltage Transformer Testing System

    KVTS - Knopp Incorporated

    The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.

  • Voltage Transformer Testing System

    KVTS - The Eastern Specialty Company

    The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.

  • DC Power Supplies

    Asterion DC Series - AMETEK Programmable Power, Inc.

    The Sorensen Asterion line of DC power supplies by AMETEK Programmable Power combines intelligence and flexibility to create an advanced platform of DC solutions in 1.7, 3.4, 5.0 & 10kW. The new DC series features two types of product lines: fixed range and autoranging. The fixed range supplies are economical, traditional rectangular wave output power supplies with all the enhanced operation advantages standard with the Asterion platform. The autoranging supplies feature expanded current and voltage range at the full output power level, enabling the ability to satisfy a wider testing need without requiring the purchase of additional models. Its groundbreaking capabilities set the standard for affordable, precision power supplies.

  • Desktop Test Interface Station

    2210 - The Eastern Specialty Company

    TESCO’s new Desktop Test Interface Station (Catalog No. 2210) provides metering professionals with exceptional testing flexibility. The Test Interface Station is ergonomically designed for meter technicians working in a lab or a desktop, yet still rugged for field use. The Test Interface Station includes a zero insertion force (ZIF) meter socket, voltage selection, form selection, open/closed-link selection and bi-directional cabling to power a load box/test kit & connect test standard potentials. When combined with a test kit/test standard and powered via 120 VAC, the Test Interface Station creates a single position, stand-alone, meter accuracy testing device for various socket based meters (both mechanical & solid-state).

  • High Voltage Impulse Test Set Up

    NEO TELE-TRONIX PVT. LTD

    We are renowned as the foremost manufacturer and exporter of High Voltage Impulse Test Set Up. This testing equipment is demanded in electrical, power generation and engineering sector. It is incorporated with fiber optic isolated digitizers to test various types of transformers. We utilize excellent grade raw materials to engineer and develop this High Voltage Impulse Test Set Up in accordance with industry standards. Our clients can get this equipment from us at competitive price.

  • Energy Meter Test Bench

    SP-6103 - Shanghai Powoo Industry Develop Group Limited

    - Single phase energy meter test bench - auto-calibration system - accuracy class: 0.1/0.2 class - Standard CT; 0.01/0.02 - output voltage: 0-220V9240V option); range: 0-120% - fine adjustment: 0.01% - output current: 0-100A; (option for 200A)- fine adjustment: 0.0001A (min)

  • Manual Flying Probe Test Systems

    atg Luther & Maelzer

    They provide flexible measurement technologies like Kelvin and high voltage tests in combination with low tooling costs. atg Luther & Maelzer offers a wide range of different systems starting from standard systems with 8 heads up to oversized systems with 24 test heads.

  • Crawler Control Unit

    CCU186 - Teledyne ICM

    The CCU186 control unit for crawlers possesses a distinct advantage compared to existing products. In fact, all of the performances that are usually achieved with standard control units are now available in the crawler configura­tion. Automatic slow preheating, the progressive rise in voltage with each exposure, as well as a selection of set values are all included in the CCU186.As the CCU186 has been entirely fitted with industrial electronic components, it is perfectly suited to the often extreme conditions of automatic intra-tube control campaigns.

  • Field Intensity Meter

    LM870-W - Sichuan Jiuzhou Electronic Technology Co.,Ltd

    * Trunk-line AC voltage, V/A, C/N and TILT measurable* Automatic over-voltage shut-off protection* AC/DC optional (Ni-H/Li storage battery inside)* Full-digital key-board operation, direct freq. & channel input* Automatic scanning, Automatic channel-filtering, Automatic error-operation amending* All standard channels and subjoin channels pre-set inside* New channel-table setting according to user's special requirement* Spectrum displaying* English/Chinese operation interface* Audio output (speaker set-in)

  • Frequency to Current Converter

    DAT4540R - Datexel

    The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.

Get Help